Service Line
+8615399723311
Application: Suitable for power supply, control circuit and other general PCB mounting/ High ripple current in PCB mounting.
Features:
Operating Temperature Range | --40~105 Deg. |
Rated Voltage Range (VDC) | 10~450 Volts |
Load Life Range | 2 Khrs (105 Deg.) |
Nominal Capacitance Range | 68~47000uF |
Nominal Capacitance Tolerance | ±20% (at 25℃ 120Hz) |
Item | Characteristics | ||||||||||
Operating temperature range | -40~+105℃(10~100Vdc) -25~+105℃(160~500Vdc) | ||||||||||
Rated voltage range | 10~500Vdc | ||||||||||
Nominal capacitance tolerance | ±20%(at 25℃ 120Hz) | ||||||||||
Leakage current | I=0.02CV or 3000μA | (25℃,5min) | 25℃,120Hz | 25℃ | |||||||
I:Leakage current | C:Nominal capacitance | V:Rated voltage | |||||||||
Dissipation factor | Rated voltage | 10 | 16 | 25 | 35 | 50 | 63~100 | 160~400 | 420~450 | at 25℃ 120Hz | |
tanδ(Max) | 0.60 | 0.45 | 0.30 | 0.25 | 0.20 | 0.15 | 0.20 | 0.24 | |||
Capacitance>1000μF:tanδ increases by 0.02 for each 1000μF from below value | |||||||||||
Load life | In the 105℃ environment, after continuous loading of DC voltage and rated ripple current for a specified time, when the product temperature is restored to 25℃ for measurement, the following requirements should be met:(at 120Hz) | ||||||||||
Capacitance change | ≦±20% of the initial value | ||||||||||
Dissipation factor | ≦200% of the initial specification value | ||||||||||
Leakage current | ≦the initial specification value | ||||||||||
Shelf life | In the 105 ℃ environment, after 1000 hours of no load, when the product temperature is restored to 25 ℃ for measurement, the following requirements should be met:(at 120Hz) | ||||||||||
Capacitance change | ≦±20% of the initial value | ||||||||||
Dissipation factor | ≦200% of the initial specification value | ||||||||||
Leakage current | ≦200% of the initial specification value | ||||||||||